【U-PM】Intelligent Power Meter

Production information
 
Multi-circuit Power Transducer (3.5mm DIN Rail / IP20)​
1 & 4 Circuit Power Meter for Options
Internal 2MB Flash Memory Capacity
Standard RS-485 Modbus communication
Isolation:AC 2KV, 50/60Hz, for 1min, 
                  Between Power / Input / Output / Case              
Order
Datasheet

The U-PM series was designed for multi-circuit power measurement, up to 12 single phase or 4 three-phase circuit power input. Applicable to different types of power circuit makes U-PM a valuable option.
Hardware standard built in a RS485 (Modbus) communication port, demand function, data logging and 2MB Flash memory. At the same time, din rail mounting provides easy installation and larger elasticity.
 

Application 

  • Electric billing management for rental buildings/apartments 
  • Marketing food stalls and mobile homes billing management
  • School dormitory/exhibition booth electricity billing management
  • Store rental booth electricity management​
 


   Ordering Information

Specifications
Electrical Characteristics   
Measurement True RMS
Sampling 128 point/Cycle
Update time 0.5 second
Metering system type 1P2W, 1P3W, 3P3W, 3P4W
Input Range Voltage: PT Primary side ratio: 100V~9999KV
               PT Secondary side ratio: 50~600V 
Direct Input: ≤600V(L-L) or ≤400V(L-N) 
Current Main circuit input: 333mV
CT Primary side ratio: 5~9999A 
Frequency 45~65Hz
Metering over range Voltage: 1.2X rated voltage continuous (600V max) 
Current: 1.2X rated current of CT
   
Power Quality   
THD Total harmonic distortion per phase, per line, average ofvoltage and per circuit, average of current.
Indicator light Power / Communication / System indicator
Power consumption DC 10~60V, 5W
   
Demand   
Calculation method Slide / Fix
Calculation cycle 1~60 minutes
   
Data Logging   
Setting 50 factors can be record at the same time.
Time interval can be set from 1~32767,
Unit can be set to day, hour, minute, second
Memory 2MB Flash ROM
   
TOU (Time of Use)  
4 Seasons 1~4 seasons per year
8 Tariff setting 1~8 each day
(For peak, mid peak, off peak per day for billing)
Parameters of TOU AE-Imp, AE-Total, RE- Imp, RE-Total, SE, SE-Total, in every circuit month and previous month. 
Yearly setting Tariff setting for 1 year or set up to 5 years
   
Pulse Output (PO)   
Output mode Open collector (O.C.)
Output 30Vdc, 30mA(max)
Energy pulse output 1600 Pulse / kWh;duty cycle 50%
   
Communication  
Protocol Modbus RTU mode
Baud rate 1200/2400/4800/9600/19200/38400/57600/115200 bps
Data bits 8 bits
Parity None / Even / Odd
Stop bit 1 or 2
Address 1~247
Distance 1200M max
Terminate resistor 120~300Ω / 0.25W (typical: 150Ω)
   
Environmental Characteristics
Operating temp. -25~70 °C
Humidity rating 5~95%RH, Non-condensing
Temp. coefficient ≤100 PPM/°C
Storage temp. -30~75°C
Storage humidity 0~95%, Non-condensing
   
Dimensions: 129.6mm(L)x47.2mm(W)x135mm(H)
Metering System Type Connection
External CT Order Information
Back to the top