Production information
The U-PM series was designed for multi-circuit power measurement, up to 12 single phase or 4 three-phase circuit power input. Applicable to different types of power circuit makes U-PM a valuable option.
Hardware standard built in a RS485 (Modbus) communication port, demand function, data logging and 2MB Flash memory. At the same time, din rail mounting provides easy installation and larger elasticity.
Application
- Electric billing management for rental buildings/apartments
- Marketing food stalls and mobile homes billing management
- School dormitory/exhibition booth electricity billing management
- Store rental booth electricity management
Ordering Information
Specifications
Electrical Characteristics | |
Measurement | True RMS |
Sampling | 128 point/Cycle |
Update time | 0.5 second |
Metering system type | 1P2W, 1P3W, 3P3W, 3P4W |
Input Range | Voltage: PT Primary side ratio: 100V~9999KV PT Secondary side ratio: 50~600V Direct Input: ≤600V(L-L) or ≤400V(L-N) |
Current | Main circuit input: 333mV CT Primary side ratio: 5~9999A |
Frequency | 45~65Hz |
Metering over range | Voltage: 1.2X rated voltage continuous (600V max) Current: 1.2X rated current of CT |
Power Quality | |
THD | Total harmonic distortion per phase, per line, average ofvoltage and per circuit, average of current. |
Indicator light | Power / Communication / System indicator |
Power consumption | DC 10~60V, 5W |
Demand | |
Calculation method | Slide / Fix |
Calculation cycle | 1~60 minutes |
Data Logging | |
Setting | 50 factors can be record at the same time. Time interval can be set from 1~32767, Unit can be set to day, hour, minute, second |
Memory | 2MB Flash ROM |
TOU (Time of Use) | |
4 Seasons | 1~4 seasons per year |
8 Tariff setting | 1~8 each day (For peak, mid peak, off peak per day for billing) |
Parameters of TOU | AE-Imp, AE-Total, RE- Imp, RE-Total, SE, SE-Total, in every circuit month and previous month. |
Yearly setting | Tariff setting for 1 year or set up to 5 years |
Pulse Output (PO) | |
Output mode | Open collector (O.C.) |
Output | 30Vdc, 30mA(max) |
Energy pulse output | 1600 Pulse / kWh;duty cycle 50% |
Communication | |
Protocol | Modbus RTU mode |
Baud rate | 1200/2400/4800/9600/19200/38400/57600/115200 bps |
Data bits | 8 bits |
Parity | None / Even / Odd |
Stop bit | 1 or 2 |
Address | 1~247 |
Distance | 1200M max |
Terminate resistor | 120~300Ω / 0.25W (typical: 150Ω) |
Environmental Characteristics | |
Operating temp. | -25~70 °C |
Humidity rating | 5~95%RH, Non-condensing |
Temp. coefficient | ≤100 PPM/°C |
Storage temp. | -30~75°C |
Storage humidity | 0~95%, Non-condensing |
Dimensions: 129.6mm(L)x47.2mm(W)x135mm(H)
|
Metering System Type Connection
External CT Order Information